Fujikura FSM-60S Fusion Splicer Kit

Condition: New
  Fujikura / FSM 60S
Special: $11,999.00
Reg. Price: $12,995.00
 
Quantity in Stock: 4
Specific Details
Includes: New Fujikura 60S fusion splicer with yellow case, btr-08 battery, ct-30a cleaver, adc013 ac adapter, dcc-14 battery charging cord, acc-14 ac power cord, spare pair of new electrodes, sheath clamp, USB cable, carrying strap and .pdf instruction manual.

SurplusEQ.com is not an AFL Distributor. AFL will not service this splicer. For service and repairs, contact SurplusEQ.com.

May be subject to stock on hand. Contact us for availability

Fujikura FSM-60S Fusion Splicer Kit w/ CT-30A Additional Information
Fujikura FSM-60S Fusion Splicer Kit   (Image A)
Our Description

We have been selling fusion splicers for almost 10 years and have sold thousands of them. Currently, we have almost 100 different splicers in stock! You won’t find other dealers with this kind of stock.

Optional Two-Year Extended Warranty available!

Get a free fusion splicer rental if repairs take more than five days. You pay only shipping & insurance. You also get all future out-of-warranty repair and calibration labor at considerably less than what AFL charges. Great deal! For what you save, you should purchase a second splicer for backup while they last!

We try to keep the Fujikura 60s kits in stock but you should always contact us early and check availability!

Item Tested?: Not Applicable (N/A)
Physical Condition: Excellent | Working Condition: Fully Functional
Fujikura FSM-60S Fusion Splicer Kit   (Image B)
Fujikura FSM-60S Fusion Splicer Kit   (Image C)
Fujikura FSM-60S Fusion Splicer Kit   (Image D)
Fujikura FSM-60S Fusion Splicer Kit   (Image E)
Manufacturer's Description
The Fujikura FSM-60S fusion splicer sets the standard for core alignment fusion splicing by incorporating a user-friendly interface with enhanced features to provide the most rugged and reliable fusion splicer in the market today. The new rugged construction adds improved reliability by resisting shock, dust, and rain, and can withstand a 30 drop test.

The FSM-60S splices a fiber in 9 seconds and heats a 60mm splice sleeve in 30 seconds, for a total cycle time of only 39 seconds. New features, such as automatic tube heater operation, user-selectable clamping method (sheath clamp or fiber holder system), automated monitor image orientation, and battery charge capability during splicer operation provide the end user a productivity tool they can
count on.

New software included provides the ability to download splice data to a PC for splice data reporting, download splicer operating software via the internet to maintain peak performance, and download video images from the splicer to enhance technical support.

Specifications
Applicable type of fibersSM (ITU-T G.652)
MM (ITU-T G.651
DS (ITU-T G.653)
NZDS (ITU-T G.655)
Fiber CountSingle
Applicable fiber dimensionsCladding Diameter: 80 to 150µm.
Coating diameter: 100 to 1000µm
Fiber setting and cleaved lengthSheathe clamp A (standard): For coating dia. up to 250µm (8 to 16mm cleave), coating dia. of over 250µm (16µm cleave)
Sheathe clamp B (option): For coating dia. up to 1000µm (8 to 16mm cleave)
Sheathe clamp C (option): For 900µm dia. loose tube fiber (8 to 16mm cleave)
Fiber holder (option): FH-60-250 and FH-60-900 (10mm cleave)
Splicing modesTotal 100 modes
Typical splice loss0.02dB with SM
0.01dB with MM
0.04dB with DS
0.04dB with NZDS
(Measured by cut-back method relevant to ITU-T standard)
Return loss>>60dB
Splicing timeTypical 9 sec. with SM FAST
10 sec. with SM AUTO
13 sec. with AUTO modes with standard SM (ITU-T G.652)
Arc Calibration Method Automatic
Real-time and by using results of previous splice when in AUTO mode
Manual arc calibration function available
Splice Loss EstimateAvailable
Attenuation splice functionIntentional high splice loss of 0.1dB to 15dB (0.1dB step) can be made for an in-line fixed attenuator.
Tube heater / heating timeBuilt-in tube heater with 30 heating modes / Typical 30 sec. with Fujikura FP-03
Applicable protection sleeve60mm 40mm and Fujikura FPS01 series
Storage of splice resultthe last 2000 results to be stored in the internal memory
Tension test1.96 to 2.25N
Operating condition0 to 5,000m above seal level, 0 to 95%RH and -10 to 50ºC and up to 15m/s wind velocity, respectively
Storage Condition0 to 95%RH and -40 to 80ºC respectively. Battery: -20 to 30º for long term
Dimensions136Wx161Dx143H (mm) excluding rubber foot
Weight2.3kg with AC adaptor ADC-13
2.7kg with battery BTR-08.
Viewing method and displayTwo CMOS cameras and 4.1" color LCD monitor
Fiber view and magnificationX/Y (300X magnification), or both X and Y simultaneously (187X magnification)
Power SupplyApplicable voltage from 100 to 240V AC or 10 to 15V DC with ADC-13. 13.2V DC with BTR-08
No. of splice cycles with batteryTypical 160 cycles (splice / tube heat) with BTR-08
Electrode Life2500 arc-discharges
TerminalsUSB 1.1 (Mini-B type) connector for PC communication.
6-pin Mini-DIN connector for HJS-02, HJS-03 or SH-8C power supply
© 2000-2009 SurplusEQ.com, Inc. All Rights Reserved